Permanent magnet DC brushless speed control electric actuator is suitable for high-precision, high-speed, frequent start-up, and harsh working conditions.
Quarter Turn : 100Nm-300,000Nm
Linear Travel : 1KN-120KN.
| Standard Configuration Technical Parameters | |
|---|---|
| Basic Parameters | BLDC Motor |
| Product Series | Secure Series High Speed / Precision / Full Function Ball / Butterfly / Control Valve |
| Power Supply | 12 / 24 / 36 / 48 / 72 VDC ±2% 110 / 230 / 400 / 600 VAC ±25% Solar + DC Electric Actuator |
| Torque / Thrust | Part-turn: 100-300000 Nm Linear: 1-120 kN |
| Speed Range | 15%-100% (Rated Motor Speed) |
| Torque Range | 2-3 Times Standard Torque (Not all models can reach 3× torque) |
| Torque Detection | Detecting the current changes during the motor operation. |
| Torque Detection Accuracy | ±3% |
| LCD / OLCD | 4 Lines Display, English and Chinese Switching. |
| Position Sensor | Absolute Encoder |
| Input / Output | Analog Quantity: 4-20 mA / 4-20 mA; Switching Quantity: Dry Contact; Wireless Remote Control (1-10 km) |
| Control Accuracy | ±0.1%, For high precision control, have to use DAUME provided valve. |
| Receive Command Response Time | 50 ms |
| Motor Commutation | Electronic Commutation |
| Motor Commutation Time Interval | Immediately (No need to stop) |
| Motor Overshoot | No Overshoot or Slight Overshoot |
| Motor Load Rate | Load Ratio: 300%, Working State: S5 Start Frequency is Not Limited |
| Ambient Temperature | -40°C to +85°C (Conventional) -60°C to +60°C (Mention in the Order) |
| Environment Humidity | 100% RH |
| Protection Level | IP69 Underwater 12 m Normally Working |
| Explosion-proof Grade | Ex dⅡ C T5 |
| Communication Protocol | ModBUS-RTU (Std) ProfiBUS-DP HART |
| Alarm Output | 6-Way Relay Alarm Output |
| Seismic Performance | Manufacturer Test Standard: At 600 Hz, 3-Axis Direction, 10 g State, It Continuously Worked Successfully for 180 Days. |
| Split Installation | Split Control Box: The Local Display, Operating Panel, Controller, etc., are placed at a location ≤40 m away. Actuator Body: The Motor, Position Sensor, etc., are fixed in the host body cavity in a special way. Split Installation Distance ≤40 m |
| Solar Power | Solar Power Supply in the Field Without Power Supply |
When choosing the actuators, customers should select suitable models based on information such as valve torque, working conditions, and valve size. It is recommended that when choosing an electric actuator model, 60% – 80% of the rated output torque of the actuator should be used as the working torque of the valve. If the application scenario is very important or the environment is complex, customers should provide design drawings and detailed parameters as much as possible for the company’s experts to review and recommend matching products.